Your VAT details were not recognised or were invalid. Your VAT number must be matched to your Billing Country as specified above. This is currently specified as . You do not need to enter the country code part of your VAT number as this has already been selected in your billing address details above.
The VAT number checking service is currently offline. Please supply your VAT details within the comments or special instructions field below and we will apply a VAT discount after placing your order request.
Air Conditioning Refrigerant Line
Fits
- Porsche 996 C4S 3.6L 09/01-2005
- Porsche 996 TURBO 2000-05
Diagram Ref No 11
What This Product Does
This line provides a sealed route for refrigerant travelling between designated components in the air-conditioning system. The supplied exploded-parts information describes the component as both a pressure line and a refrigerant line within the applicable 996 assemblies.
Functions
- Carries refrigerant through the air-conditioning circuit
- Connects the relevant factory climate-control components
- Helps retain the refrigerant charge within a sealed system
- Supports normal cooling and dehumidification when the system is correctly serviced
Technical Details
- Genuine Porsche component
- Part number: 99657309405
- Exploded-diagram descriptions: pressure line and refrigerant line
- Quantity shown: one per applicable diagram assembly
- Identified for C4S in the refrigerant circuit 996 1998–05 diagram
- Also referenced in the refrigerant circuit 996 TURBO 2001–05 diagram
Symptoms of Fault
- Cooling performance gradually becomes weaker or warm
- The system loses its refrigerant charge after servicing
- Oily residue or leak-detection dye appears near the line or connections
- Corrosion, abrasion, cracking or impact damage is visible
- Hissing may be present where a significant leak has developed
- Demisting performance is reduced when cooling and dehumidification are needed
Why Replacement Matters
A leaking or damaged line prevents the air-conditioning circuit from retaining the correct refrigerant charge. Renewing the affected component enables the system to be leak-tested, evacuated and recharged correctly rather than relying on repeated regassing. Inspect the connection seals, retaining supports and adjacent pipework during installation. Refrigerant recovery and charging require suitable air-conditioning service equipment.
FAQs
- Does weak cooling confirm that this line is faulty?
No. Refrigerant may escape from several points in the circuit, so diagnosis and leak testing should be completed before replacement. - Can the system be used without recharging after installation?
No. Once opened, the circuit must be evacuated, checked for leak tightness and filled with the specified refrigerant quantity. - Should the connection seals also be inspected?
Yes. Hardened or damaged O-rings can cause leakage even when the line itself remains sound. - How should compatibility be checked?
Confirm part number 99657309405 against the vehicle identification number, model year and exact air-conditioning configuration.
Related reference numbers
Related, superseded, cross reference or alternative numbers for comparison.
99657309405
The product you are viewing cross references to these numbers
- Porsche 996 C4S 3.6L 09/01-2005
- Porsche 996 TURBO 2000-05